Ask Latest Price
Brand Name :Huanghe
Model Number :ACSR AAC ACC
Certification :IOS OHSAS CCC IEC
Place of Origin :China
MOQ :200
Price :0.1-10USD
Payment Terms :TT/Western Union /LC
Supply Ability :50000meters per week
Delivery Time :5-8days
Packaging Details :coils, wooden drums, steel drums or steel-wooden drums
Application :Overhead
Insulation material :None, bare
Jacket :None, Bare
Standard :ASTM B232, IEC61089, GB/T 1179-2008 etc.
Packing :coils, wooden drums, steel-wooden drums
Warranty :1 Year
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

ASTM B232 Bare Conductor Bare ACSR AAC AAAC ACC , Overhead Conductors

BARE CONDUCTOR TYPE

Bare Conductor Types Description Nominal Section-area (mm2)
ACC All Copper Conductor

16, 25, 35, 50, 70, 95, 120,

150, 185, 210, 240, 300, 400, 500, 630, 800

AAC All Aluminum Conductor
AAAC All Aluminum Alloy Conductor
ACSR Aluminum Conductor Steel Reinforced

BARE CONDUCTOR FEATURE

1. High tensile strength

2. Long life

3. Light in weight

4. Suitable for high as well as extra high overhead voltage lines

BARE CONDUCTOR STANDARD

ASTM B232, IEC61089, BS215, DIN48204, BS EN50182, GB/T 1179-2008 etc.

ASTM B232 Bare Conductor Bare ACSR AAC AAAC ACC , Overhead Conductors

BARE CONDUCTOR DESCRIPTION

AAAC, ACSR form part of the family of Overhead Conductors, Transmission Conductors and Power Distribution Conductors. These cables are formally known as All Aluminium Conductor (AAC), All Aluminium Alloy Conductor (AAAC) and Aluminium Conductor Steel Reinforced (ACSR). These overhead conductors are used as power transmission and distribution lines. All aluminium conductors are made up of one or more strands of aluminium wire depending on the specific application.

AAC–ASTM-B ALL ALUMINUM CONDUCTOR

AAC conductor is also known as aluminium stranded conductor. It is manufactured from electrolytic ally refined aluminium, witha minimum purity of 99.7%. AAC is used mainly in urban areas where the spacing is short and the supports are close. All aluminium conductors are made up of one or more strands of aluminium wire depending on the end usage. AAC is also used extensively in coastal regions because it has a high degree of corrosion resistance.

ASTM B232 Bare Conductor Bare ACSR AAC AAAC ACC , Overhead Conductors

AAAC-ASTM-B ALL ALUMINUM ALLOY CONDUCTOR

AAAC are used as a bare conductor cable on aerial circuits that require a larger mechanical resistance than the AAC and a better corrosion resistance than the ACSR. The sag characteristics and the strength-to-weight ratio of the AAAC conductor cable is better than both AAC and ACSR.

ACSR-ASTM-B ALUMINUM CONDUCTOR STEEL REINFORCED

ACSR is available in a range of steel contents ranging from 6% to 40% for additional strength. The higher strength ACSR conductors are commonly used for river crossings, overhead earth wires, and installations involving extra-long spans. The ACSR conductor can, against any given resistance, be manufactured to different tensile strengths, so a high tensile strength combined with its lightweight properties means it can cover longer distances with fewer supports. Due to the greater diameter of the ACSR conductor, a much higher corona limit can be obtained which is advantageous on high and extra high voltage overhead lines.

Aluminium conductors are known by codenames, differing depending on dimensions. Bare conductor sizes are available as AWG in cmill, kcmill and MCM.

We could producing according to the customers' requirements. Welcome your request for any quotations.

ALUMINUM CONDUCTOR STEEL REINFORCED (ACSR) BARE CONDUCTOR DATA

Code name Nominal Area Stranding&Wire Diameter Dia. Sectional Area Wight Breaking Load

DC Re.

at 20℃

Current Rating
Al. St. Al. St. Total
mm2 No. mm No. mm mm mm2 mm2 mm2 Kg/Km kN Ω/Km A
Gopher 25 6 2.36 1 2.36 7.08 26.2 4.37 26.2 72.1 9.61 1.093 126
Weasel 30 6 2.59 1 2.59 7.77 31.6 5.3 36.9 128 11.45 0.9077 134
Ferret 40 6 3 1 3 9 42.4 7.1 49.5 171.7 15.2 0.6766 161
Rabbit 50 6 3.35 1 3.35 10.05 52.9 8.8 61.7 214.1 18.35 0.5426 185
Horse 70 12 2.79 7 2.79 13.95 73.4 42.8 116.2 538.1 61.2 0.3936 268
Dog 100 6 4.72 7 1.57 14.15 105 13.6 118.5 394.7 32.7 0.2733 278
Wolf 150 30 2.59 7 2.59 18.13 158.1 36.9 194.9 725.9 69.2 0.1828 355
Dingo 150 18 3.35 1 3.35 16.75 158.7 8.8 167.5 507.4 35.7 0.1815 349
Lynx 175 30 2.79 7 2.79 19.53 183.4 42.8 226.2 842.4 79.8 0.1576 386
Caracal 175 18 3.61 1 3.61 18.05 184.2 10.2 194.5 589.2 41.1 0.1563 383
Panther 200 30 3 7 3 21 212.1 49.5 261.5 974 92.25 0.1363 421
Jaguar 200 18 3.86 1 3.86 19.3 210.6 11.7 222.3 673.6 46.55 0.1367 415
Zebra 400 54 3.18 7 3.18 28.62 428.9 55.6 484.5 1621.3 131.9 0.06741 635

ASTM B232 Bare Conductor Bare ACSR AAC AAAC ACC , Overhead Conductors

Inquiry Cart 0