IEC Standard Great Rubber Jacket Flexible Rubber Cable
Model: YC/YCW
Voltage: 300/500v,450/750v
Conductor Material: Copper
Insulation Material: Ethylene propylene rubber
Jacket Material: Natural rubber/Chloroprene rubber
Conductor Type: Soft Conductor
Operating temperature: Cable conductor long-term maximum allowable working temperature of 65 ℃; short circuit, the cable conductor maximum temperature does not exceed 160 ℃, the duration of not more than 5S.
Environmental Temperature: The cable runs at a minimum ambient temperature of -10 ° C..
Laying temperature: Installation laying, the temperature should not be less than -10 ℃.
Bending radius: Cable bending radius of not more than 10D..
Color: green / yellow, light blue, black, brown,or according to customer requirements
Product Specificatio
Model | Specification/mm2 | Rated voltage(V) | Core |
YQ/YQW | 0.3-0.5 | 300/500 | 2 , 3 |
YZ / YZW | 0.75-6 | 450/750 | 2, 3 , 4, 5 |
YC / YCW | 1.5-400 1.5-95 1.5-120 1.5-120 | 450/750 | 1 2 3 , 4 5 |
YH / YHW | 6-185 | 200 | 1 |
High temperature resistance, Low temperature resistance, Flexible and Corrosion resistance.
Core numbers | Wire core of | Insulator | Normal insulated | Outer diam | Outer diam | Conductor resistance at 20 | |
Cu core | Tinning cu-core | ||||||
2×0.75 | 24/0.20 | 0.6 | 0.8 | 6.28 | 7.22 | 26 | 26.7 |
2×1.. | 32/0.20 | 0.6 | 0.9 | 6.84 | 7.87 | 19.5 | 20 |
2×1.5 | 30/0.25 | 0.7 | 1 | 8 | 9.2 | 13.3 | 13.7 |
2×2.5 | 49/0.25 | 0.8 | 1.1 | 9.2 | 10.58 | 7.98 | 8.21 |
3×0.75 | 24/0.20 | 0.6 | 0.9 | 6.84 | 7.87 | 26 | 26.7 |
3×1.00 | 32/0.20 | 0.6 | 0.9 | 7.23 | 8.31 | 19.5 | 20 |
3×1.5 | 30/0.25 | 0.7 | 1 | 8.46 | 9.73 | 13.3 | 13.7 |
3×2.5 | 49/0.25 | 0.8 | 1.1 | 9.96 | 11.45 | 7.98 | 8.21 |
4×0.75 | 24/0.20 | 0.6 | 0.9 | 7.48 | 8.58 | 26 | 26.7 |
4×1.00 | 32/0.20 | 0.6 | 0.9 | 7.88 | 9.06 | 19.5 | 20 |
4×1.5 | 30/0.25 | 0.7 | 1 | 9.44 | 10.86 | 13.3 | 13.7 |
4×2.5 | 49/0.25 | 0.8 | 1.2 | 11.09 | 12.75 | 7.98 | 8.21 |
2×4 | 56/0.30 | 1 | 1.8 | 12.8 | 14.72 | 4.95 | 5.09 |
2×6 | 84/0.30 | 1 | 2 | 15.2 | 17.48 | 3.3 | 3.39 |
2×10 | 84/0.40 | 1.2 | 3.1 | 20.2 | 23.23 | 1.91 | 1.95 |
2×16 | 126/0.40 | 1.2 | 3.3 | 22.8 | 26.22 | 1.21 | 1.24 |
2×25 | 196/0.40 | 1.4 | 3.6 | 27 | 31.05 | 0.78 | 0.795 |
2×35 | 276/0.40 | 1.4 | 3.9 | 30.4 | 34.96 | 0.554 | 0.565 |
3×4 | 56/0.30 | 1 | 1.9 | 13.7 | 15.75 | 4.95 | 5.09 |
3×6 | 84/0.30 | 1 | 2.1 | 16.3 | 18.74 | 3.3 | 3.39 |
Rubber Sheath PVC Insulated Flexible Rubber Cable
4 cores 16sqmm 450/750V Flexible Rubber Cable
1.Electrical cable comply with the national standard, application in construction, made by copper , rubber insulated.
2. Flexible Rubber Cablerated voltage 450/750V maximum direct current resistance of the con duc tor at 20.C and current carrying capacity below environmental temperature 40.C
3. Flexible Rubber Cable Specification:
cross-section (mm2) | 1.5 | 2.5 | 4 | 6 | 10 | 16 | 25 | 35 | 50 | 70 | 95 | 120 | 150 | 185 | 240 |
| 13.3 | 7.98 | 4.95 | 3.3 | 1.91 | 1.21 | O.78 | O.55 | O.39 | O.27 | O.21 | O.16 | O.13 | O.11 | O.08 |
| 14 | 20 | 27 | 34 | 48 | 67 | 92 | 115 | 141 | 180 | 225 | 264 | 312 | 359 | 440 |
Number of wirexNominal cross sectional area (mm) | Outer diameter of cable, approx (mm) | Weight of cable, approx Kg/Km | Number of f ewirex Nominal cross sectional area (mm) | Outer diameter of cable, approx (mm) | Weight of cable, approx Kg/Km |
3x4+6x1.5 | 6.5x45.5 | 525 | 3×50+1×16+5×2.5+ 2×p1.5
| 17.5×76.5 | 2932 |
3x6+6x1.5 | 7.8x54.2 | 736 | 3×70+1×25+5×2.5+ 2×p1.5
| 19.8×86 | 3895 |
6x10+6x2.5 | 11x71.2 | 1500 | 3×95+1×35+5×2.5+ 2×p1.5
| 22.8×99 | 5124 |
3x10+3x6+3x4+5x2.5 | 19.7X68.7 | 2076 | 3×120+1×35+5×2.5+2×p1.5
| 25.8×112
| 6450 |
6x16+6x2.5 | 22.7x64.6 | 2378 | 3×120+1×35+4×4 | 25.8×112
| 6428 |
6x25+6x2.5 | 15.6x92.4 | 2723 | 3×120+2×16+4×4
| 28.1×99.4
| 6031 |
3x25+1x10+5x2.5+2xpl.5 | 14.6x63 | 1859 | 3×150+1×50+5×2.5+2×p1.5 | 27.6×121
| 7741 |
3x35+1x10+5x2.5+2xpl.5 | 14.7x63.5 | 2040 | 3×150+1×50+4×4 | 27.6×121
| 7723 |